JTN1SPADC12V,JTN1SPADC15V,JTN1SPADC17V,JTN1SPADC24V,JTN1SPADC5V,JTN1SPADC6V,JTN1SPADC9V,J

Part No.:
JTN1SPADC12V,JTN1SPADC15V,JTN1SPADC17V,JTN1SPADC24V,JTN1SPADC5V,JTN1SPADC6V,JTN1SPADC9V,J
Download:
Download
Description:
COMPACT ECONOMICAL 30 AMP. RELAY
File Size:
93 K
Page:
4 Pages
Logo:
Maker:
NAIS [ NAIS(MATSUSHITA ELECTRIC WORKS) ]
PCB Prototype

July 16, 2018:

K-229064-10-1A

L2-R82

L6935TR

LAN83C180

LBW1000

LC242

LG-110G-CTR-RB

LGPDW5V015RPMRT001

LHB2SB3

LM4F111B2QR

LM4F212H5BB

LMH0395

PCB Datasheet:1PCB Datasheet:1
COMPACT ECONOMICAL
30 AMP. RELAY
JT-N·JT
RELAYS
FEATURES
• High switching capacity — 30 A for 1 Form A
• 2 contact arrangements — 1 Form A or 1 Form C
• Sealed and “TMP” types available
• UL/CSA recognized ( PCB Prototyping & TMP type: UL508
group A spacing, UL873 spacing)
• Class F types standard for PCB & TMP type
PCB type
TMP type
Open type
SPECIFICATIONS
Contacts
Arrangement
PCB & TMP type
1 Form A
1 Form C
Open type
1 Form A
1 Form C
Characteristics
Initial insulation resistance*
1
Between contacts
Initial
breakdown
Between contacts
voltage*
2
and coil
Operate time*
3
(at nominal voltage)
N.C.:
2770 VA, 300 W
N.O.:
5440 VA, 600 W
Release time (without diode)*
3
(at nominal voltage)
Functional*
4
Shock
resistance
Destructive*
5
Vibration
resistance
Functional*
6
Destructive
PCB & TMP type
Open type
Min. 100 MOhm at 500 V DC
1,200 Vrms
2,500 Vrms
1,500 Vrms
1,500 Vrms
Initial contact
resistance, max.
(By voltage drop
method, 6 V DC 1
A)
Contact material
Max. switch-
ing power
Rating
Max. switch-
ing voltage
Max. switch-
ing current
50
mOhm
20 mOhm
Max. 15 ms
Max. 10 ms
Min. 98 m/s
2
{10 G}
Min. 980 m/s
2
{100 G}
Max. 88.2 m/s
2
{9 G}, 10 to 55 Hz
at double amplitude of 1.5 mm
Max. 117.6 m/s
2
{12 G}, 10 to 55 Hz
at double amplitude of 2 mm
–55°C to +85°C
–67°F to +185°F
Silver alloy
8310 VA
N.C.: 2770 VA
N.O.: 5440 VA
8310 VA
900 W
277 V AC
30 A
N.C.: 10 A
N.O.: 20 A
277 V AC, 30 V DC
30 A
N.C.: 10 A
N.O.: 20 A
Min. 1x10
7
N.O.:
Expected life
20 A 277 V AC
Mechanical
20 A 277 V AC
Min. 1x10
5
*
Electrical
5
N.C.:
(Resistive load)
Min. 1x10 *
10 A 277 V AC
Min. 1x10
5
*
N.O.:
20 A 277 V AC
20 A 30 V DC
30 A 277 V AC
Min. 1x10
5
30 A 30 V DC
N.C.:
Min. 1x10
5
10 A 277 V AC
10 A 30 V DC
Min. 1x10
5
Conditions for
Ambient
operation, trans-
temp.
port and storage*
7
(Not freezing and
condensing at low
Humidity
temperature)
5 to 85% R.H.
Unit weight
* For sealed types, the life shown is for open venting-hole condition.
PCB type:
Approx. 25 g
(.88 oz)
TMP type:
Approx. 30 g
(1.06 oz)
Approx.
20 g
(.71 oz)
Coil
at 20°C
68°F
JT-N
PCB & TMP type
Approx. 450 mW
Approx. 800 mW
JT
Open type
Approx. 500 mW
Approx. 900 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Intial breakdown voltage” section
*
2
Detection current: 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10µs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10µs
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Minimum operating power
Nominal operating power
TYPICAL APPLICATIONS
• Automotive
• Air conditioner
• Heating & ventilation
• Home appliance
342